CAT6A cable (Category 6A, “Augmented Category 6”) is a twisted-pair Ethernet cable specified for 500 MHz bandwidth and 10 Gbps data transmission over a full 100-meter channel. It is designed to support 10GBASE-T reliably while controlling alien crosstalk—the interference that arises between adjacent cables in high-density bundles. CAT6A is the minimum copper cabling category explicitly specified for alien crosstalk performance, making it the preferred structured cabling choice for enterprise networks, data centers, and high-PoE deployments.
Cat5e (Enhanced Category 5): Supports 1 Gbps at 100 MHz over 100 meters. Suitable for basic Gigabit networking but not specified for 10GBASE-T.
Cat6 (Category 6): Supports 10 Gbps over limited distances (typically up to 55 meters) and 1 Gbps at full 100 meters. Bandwidth is 250 MHz.
Cat6A (Augmented Category 6): Supports full 10 Gbps at 100 meters with 500 MHz bandwidth. Specified for alien crosstalk control; backward compatible with Cat6 and Cat5e.
Cat7 / Cat7a: Specified to 600 MHz / 1000 MHz respectively, but require proprietary connectors (GG45/TERA) to achieve rated performance. Terminated with standard RJ45, they perform at Cat6A levels in practice.
Cat8: Supports 25 Gbps or 40 Gbps over short distances (typically 30 meters) with 2000 MHz bandwidth. Intended for data center switch-to-server links, not general horizontal cabling.
The shielding designation follows ISO/IEC naming: the first letters describe the overall shield, and the latter letters describe the per-pair shield.
U/UTP (Unshielded/Unshielded Twisted Pair): Four unshielded twisted pairs with no overall shield. CAT6A U/UTP relies on construction techniques—larger conductors (23 AWG minimum), tighter twists, an internal separator, and increased airspace—to suppress internal crosstalk and alien crosstalk without a foil barrier.
F/UTP (Foiled/Unshielded Twisted Pair): An overall aluminum foil shield surrounds four unshielded twisted pairs. The foil reflects EMI/RFI from external sources (lighting, machinery, wireless access points) and prevents signal leakage, improving performance in electrically noisy environments.
S/FTP (Screened/Foiled Twisted Pair): Each pair is individually foil-shielded, and an overall copper braid screen surrounds all four pairs. This provides the highest level of EMI immunity and alien crosstalk suppression, but requires compatible shielded connectors and proper grounding at both ends.
AWG (American Wire Gauge): Indicates conductor thickness. CAT6A cables commonly use 23 AWG solid bare copper for horizontal and premise runs, providing lower DC resistance and superior signal integrity at 500 MHz over 100 meters. 26 AWG stranded conductors are also used in flexible patch cords and high-density data center applications where bend radius and routing flexibility are priorities; these are rated for shorter channel lengths or specific high-flex deployments. Lower AWG numbers mean thicker conductors; 23 AWG is the reference gauge for full-distance CAT6A permanent links.
Data center and enterprise backbones — switch-to-server links, end-of-row architectures, and computer clusters requiring deterministic 10GBASE-T performance.
High-density patching — server racks, network closets, and cross-connects where cable diameter and bend radius matter.
Wi-Fi 6 / Wi-Fi 6E and in-building 5G access points — backhaul and PoE runs for next-generation wireless infrastructure.
Power over Ethernet (PoE / PoE+ / PoE++) — supports up to 100 W PoE with appropriate thermal and bundle considerations; shielded variants maintain shield continuity for PoE++ deployments.
Mission-critical and extended-distance PoE — supports 1 GbE with PoE up to 155 m in compatible end-to-end systems.
High-definition video and AV-over-IP — broadband video, voice, and IP-based audiovisual distribution.
Full 10G at 100 Meters: Cat6A guarantees 10GBASE-T over the complete 100-meter channel; Cat6 reaches 10G only over shorter runs (typically 55 meters). This eliminates distance-based performance planning for 10G uplinks and backbone links.
Specified Alien Crosstalk Control: CAT6A is the first copper category with explicit alien crosstalk (ANEXT/PS-ANEXT) specifications up to 500 MHz. This is critical in bundled cable trays and high-density pathways where adjacent cables induce noise into each other.
Double the Bandwidth of Cat6: 500 MHz versus 250 MHz provides headroom for 2.5G/5GBASE-T, higher-order modulation, and future protocol upgrades without re-cabling.
Superior PoE Thermal Performance: CAT6A’s larger conductors and, in shielded variants, metallic shield layers improve heat dissipation, supporting higher PoE levels (up to 100 W) with greater bundle density than Cat5e or Cat6.
Backward Compatibility: Fully compatible with Cat6 and Cat5e connectors, patch panels, and active equipment, allowing phased migration to 10G infrastructure.
Direct Connection: Terminate CAT6A cable with Cat6A-rated RJ45 plugs, jacks, or patch panels. The larger conductor gauge (23 AWG) and thicker overall diameter require connectors specifically rated for Cat6A conductor sizes; using Cat5e or Cat6 connectors may not maintain Cat6A performance margins. Maintain pair twists as close to the termination point as possible.
Shielded System Grounding: When using F/UTP or S/FTP cable, use shielded RJ45 connectors and shielded patch panels, and ensure the cable shield is bonded to ground at both ends through the connector housing or a drain wire. Proper grounding is essential for the shield to function as an EMI barrier.
Patch Cord vs. Permanent Link: Use stranded-conductor Cat6A patch cords (commonly 26 AWG) for flexible equipment connections, and solid-conductor Cat6A cable (23 AWG) for permanent horizontal runs. Mixing stranded and solid conductors is acceptable; performance is governed by the lowest-rated component in the channel.
Field-Termination Tools: Cat6A jacks typically require a 110-type punch-down tool or manufacturer-specific termination tool. For field-installed plugs, use a crimping tool matched to the connector’s conductor size range; verify continuity and performance with a cable certifier rated to Cat6A/Class E<sub>A</sub>.
Cat6A U/UTP, F/UTP, and S/FTP bulk cable in 305 m (1000 ft) easy-pull boxes or reels; 500 m reels available for large projects.
Cat6A patch cords in standard lengths (0.5 m, 1 m, 2 m, 3 m, 5 m, 10 m) and custom lengths.
Slim / small-OD Cat6A patch cords for high-density patching.
LSZH, CMR, and CMP-rated jacket variants for indoor, riser, and plenum installations.
Cat6A-rated RJ45 plugs (solid and stranded conductor versions).
Cat6A keystone jacks, modular jacks, and patch panels.
Shielded RJ45 connectors and shielded patch panels for F/UTP / S/FTP systems.
Field-terminable plugs and strain-relief boots.
Installation Accessories:
Cable management clips, ties, and hook-and-loop fasteners.
Cable certifiers / testers rated to Cat6A/Class E<sub>A</sub>.
Pulling grips and cable lubricant for long pulls.
Protective caps for unused ports and connectors.
CAT6A cables are manufactured and verified against the following standards:
|
Standard |
Description |
|
ANSI/TIA-568.2-D (Category 6A) |
U.S. balanced twisted-pair cabling standard; specifies 500 MHz and alien crosstalk requirements for 10GBASE-T |
|
ISO/IEC 11801 (Class E<sub>A</sub>) |
International generic cabling standard for 500 MHz balanced cabling |
|
EN 50173-1 |
European generic cabling standard, Class E<sub>A</sub> |
|
IEC 61156-5 |
International sectional specification for balanced cables up to 600 MHz |
|
UL / ETL Listed |
Safety and performance verification; flame ratings include CM, CMR, and CMP |
|
RoHS Compliant |
Restriction of Hazardous Substances |
|
CE Marked |
European conformity for safety and environmental requirements |
Reputable CAT6A cable suppliers can typically provide:
Third-Party Cable Verification — ETL or UL verification to ANSI/TIA-568.2-D Category 6A and ISO/IEC 11801 Class E<sub>A</sub>.
UL / ETL Listings — safety compliance and flame-rating verification (CMR, CMP).
Flame Retardant Certificates — CMP (plenum), CMR (riser), and LSZH test reports.
RoHS & REACH Compliance — environmental and chemical safety documentation.
ISO 9001 — quality management system certification.
EMI / Alien Crosstalk Test Reports — power-sum ANEXT and PS-ACR results at 500 MHz.
Material Test Reports — conductor gauge verification (23 AWG / 26 AWG), shielding coverage, and jacket tensile/elongation properties.
|
Parameter |
Specification |
|
Pair Count |
4 twisted pairs (8 conductors) |
|
Conductor Material |
Solid bare copper (23 AWG for permanent link); stranded bare copper (26 AWG for patch cords) |
|
Shielding Options |
U/UTP (unshielded); F/UTP (overall foil); S/FTP (pair foil + overall braid) |
|
Jacket Material |
PVC, LSZH, or plenum-rated PVC (CMP); riser-rated PVC (CMR) |
|
Bandwidth |
500 MHz (characterized to 550 MHz in some constructions) |
|
Data Rate |
10 Gbps (10GBASE-T) up to 100 m channel |
|
Supported Protocols |
10GBASE-T, 5GBASE-T, 2.5GBASE-T, 1000BASE-T, 100BASE-TX, PoE / PoE+ / PoE++ (up to 100 W) |
|
Characteristic Impedance |
100 ± 15 Ω |
|
Nominal Velocity of Propagation |
~69% (varies by insulation) |
|
Operating Temperature |
−20 °C to +75 °C (typical; LSZH and plenum variants may differ) |
|
Outer Diameter |
Typically 6.9 mm – 7.7 mm, depending on shielding and AWG |
|
Bend Radius |
4 × OD (fixed) / 8 × OD (flexed) |
CAT6A cables are typically packaged using the following methods:
Easy-Pull Box — 305 m (1000 ft) box with internal spool; standard for structured cabling contractors.
Reel / Wooden Drum — 500 m or 305 m reels for large projects and bulk distribution.
Coil / Shrink Wrap — shorter lengths (100 m) for smaller installations or retail.
Patch Cord Poly Bag — individual patch cords with protective caps on both RJ45 plugs.
Custom Packaging — OEM/ODM branding, custom box printing, and private-label reel labels available upon request.
To request a quote for CAT6A cable, please provide the following information and contact sales06@tldcable.com:
Shielding type (U/UTP / F/UTP / S/FTP)
Conductor gauge (23 AWG solid / 26 AWG stranded)
Jacket rating (PVC / LSZH / CMR / CMP)
Required length per unit (305 m box / 500 m reel / custom)
Color preference
Order quantity (boxes/reels or total meters)
Sample order or bulk order?
Custom lengths or pre-terminated assemblies?
Custom jacket color and print legend?
Shielded or unshielded connector/panel compatibility requirements?
OEM/ODM packaging and branding?
Specific third-party verification needed (ETL, UL)?
Flame-rating test reports (CMP, CMR, LSZH)?
RoHS / REACH documentation?
Destination country/port
Preferred shipping method (air, sea, express)
Required delivery timeline
Fiber Optic Cables
USB C Cables
DP Cables
HDMI Cables
Patch Cord Cables
Computer Monitor Cables
Starlink Cables